8.7 Routing constraints
8.7.1 Power supply
Since the maximum peak current can reach 2 A, Sierra Wireless strongly
recommends having a large width for the layout of the power supply signal (to
avoid voltage loss between the external power supply and the AirPrime SL808X
Embedded Module supply).
Pins 42 and 44 of the AirPrime SL808X Embedded Module should be gathered in
the same piece of copper, as shown in the figure below.
Figure 8-2: Power supply routing example
Filtering capacitors near the AirPrime SL808X Embedded Module power supply
are also recommended (22 µF to 100 µF).
Attention should be paid to the ground track or the ground plane on the
application board for the power supply which supplies the AirPrime SL808X
Embedded Module. The ground track or the ground plane on the application
board must support current peaks as well as with the VCC_3V6 track.
If the ground track between the AirPrime SL808X Embedded Module and the
power supply is a copper plane, it must not be parceled out.
The routing must be done in such a way that the total line impedance could be
10m @ 217Hz. This impedance must include the bias impedances.
The same care should be taken when routing the ground supply.
If these design rules are not followed, phase error (peak) and power loss could
occur.
8.7.1.1 Ground plane and shielding connection
The AirPrime SL808X Embedded Module has LGA ground pads linked to the
ground. The ground has to be connected to the application board through a
complete layer on the PCB.
Pin 44
Pin 42